  1. ProfiSignal (and the USB driver) but with signature enforcement enabled, the process will be a little more complicated: Post-Installation Disabling of Driver Enforcement: Part 1. Removing the driver. Run the setup again and choose Modify, then choose Next. Now remove the checked sign at Expert Key Series USB driver and press Next.
  2. Delphin systems (comprised of ProfiSignal software, Expert series and Message hardware) are open systems that can operate with external software such as Instruments™ LabVIEW™, DASYLab™ and Diadem™ through API interfaces and the corresponding drivers. ProfiSignal API.
DelphinDelphin

Delphin has developed a special device driver to enable the simple operation of Expert and Message hardware with LabVIEW™. The driver includes predefined VIs (virtual instruments) that are automatically copied into the corresponding LabVIEW™ folder on installation. The device driver is then immediately available in LabVIEW™. Fast and easy access. Delphin's new DASYLab™ device driver gives users fast and easy access to measurement data in the Expert and Message devices for DASYLab™- Versions 8 and 9 to 12. The device driver transfers online to DASYLab™ all data that has been made available by the ProfiSignal-DataService. This enables such data to be instantly processed by the data acquisition software.

Delphin's new DASYLab™ device driver gives users fast and easy access to measurement data in the Expert and Message devices for DASYLab™- Versions 8 and 9 to 12.

The device driver transfers online to DASYLab™ all data that has been made available by the ProfiSignal-DataService. This enables such data to be instantly processed by the data acquisition software. DASYLab™ can access data from Delphin's PC-based Expert Key, from Delphin's Message systems and from third-party hardware and software.

Drivers

Delphin's device driver for DASYLab™ is ideally structured with data transfer regulated via two modules.

An input module accepts the data and makes it available within DASYLab™. DASYLab™ settings can then be made using the configurations dialog. The block size for the data to be transferred is automatically calculated thereby simplifying the process for the user.

Drivers Delphin

An output module regulates the transfer of data to the Delphin hardware.

Pre-computed FFT data within the Message devices can also be read out.

Driver properties

  • Easy input and output of measurement data
  • Device driver is installed directly into DASYLab™
  • Fast data access
  • Capable of accessing Message device software channels
  • Available for Expert Key, LogMessage, TopMessage and ProfiMessage
  • Transfer of pre-computed FFT data
  • DASYLab™ 8 and 9 to 12
  • Specific DASYLab™ applications for Delphin hardware

Description

Expert Logger 400 Data Acquisition System

Drivers Define Computer Terms

The Expert Logger 400 is Delphin‘s new generation of data loggers. It combines the latest communication technology with advanced measurement technology and is based on FPGA technology to make it especially powerful. It can process up to 16 analog input channels at both low and high rates of sampling. Measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC for evaluation via USB, LAN, WLAN or LTE.

Operation Made Simple

Sensors are connected via plug-in screw terminals and a chart clearly shows how channels are arranged. Users always have a good overview of the channels despite their high density. Each set of four terminals can be configured as two differential inputs to measure voltage, currents, thermocouples, or to take measurements from a 4-wire RTD.

Configuration – Fast and Easy

The Expert Logger 400 is simple to configure from a PC. These settings remain stored within the Expert Logger even when disconnected from the power supply. The device settings can also be read out and stored on a PC and analyzed offline without the need for a connected Expert Logger. The offline configuration settings are then simply read into the device when connected. The software used for configuration is simple to operate to let users fully focus on their measurement tasks.

Drivers Definition Slavery

Intelligent Signal Processing

Definition

Drivers Definition Computer Term

Signal processing using internal software channels significantly simplifies measurement tasks. Flexible calculation channels enable measurement data to undergo further computation and recording. Integrators directly calculate volumes or quantities from time-related measurement data such as mass and discharge flow rates. Limit values can monitor measurement data and be used to switch digital outputs or automatically send emails. Complex signal processing is possible using pulse counters, stop-clock functions, and operating-hours counter. Averages can be calculated and recorded as time-weighted or moving. The Expert Logger‘s software channels clearly set it apart from other loggers and make it very popular among users.

Applications

See Full List On Delphin.com

  • Data logging
  • Environmental measurement technology
  • Product testing
  • Measurement data diagnosis
  • Lab data acquisition
  • Trials and tests